设为首页 加入收藏 登录旧版
Crowe Ⅲ型髋关节发育不良患者THA术中臼杯位置/大小和宿主骨覆盖率的比较
Comparison of acetabular cup position/size and host bone coverage ratio during THA in patients with Crowe type Ⅲ hip dysplasia
投稿时间:2022-02-24  修订日期:2022-07-11
DOI:10.3969/j.issn.1672-5972.2022.06.005
中文关键词:  髋关节发育不良  全髋关节置换  三维模拟  高旋转中心技术
英文关键词:Hip dysplasia  Total hip arthroplasty  3D simulation  High hip center technique
基金项目:
作者单位E-mail
王帅* 哈尔滨医科大学附属第一医院黑龙江 哈尔滨150000 2985416345@qq.com 
杜俊炜 新疆医科大学附属肿瘤医院新疆 乌鲁木齐830000  
刘广宇 哈尔滨医科大学附属第一医院黑龙江 哈尔滨150000  
刘帅 哈尔滨医科大学附属第一医院黑龙江 哈尔滨150000  
张衍 哈尔滨医科大学附属第一医院黑龙江 哈尔滨150000  
耿硕* 哈尔滨医科大学附属第一医院黑龙江 哈尔滨150000 31018070@qq.com 
摘要点击次数: 234
全文下载次数: 220
中文摘要:
      目的 探讨髋关节发育不良(DDH)Crowe Ⅲ型患者行THA时在不同位置安放髋臼杯其臼杯的大小和宿主骨覆盖率。方法 通过对纳入的2017年9月至2021年10月于哈尔滨医科大学附属第一医院就诊的20例DDH Crowe Ⅲ型患者进行骨盆、股骨三维模型重建,分别于真臼位置、假臼位置、真假臼之间骨量最丰富处选择合适尺寸的髋臼杯进行模拟安放,并计算髋臼杯宿主骨覆盖率。得出数据分为真臼组、中间组、假臼组。结果 中间组及假臼组重建的臼杯尺寸大于真臼组,真臼组与其他两组的差异均具有统计学意义,中间组与假臼组臼杯尺寸差异无统计学意义。各组的髋臼杯覆盖率均值都在75%以上,其中中间组与假臼组差异具有统计学意义。结论 对于DDH Crowe Ⅲ型患者的THA来说,于假臼或真假臼之间安放髋臼杯可获得较大的臼杯尺寸和满意的宿主骨覆盖率。
英文摘要:
      Objective To explore the cup size and host bone coverage ratio of acetabular cups at different positions where they are placed in THA for DDH Crowe typeⅢ patients.Methods 3D models of pelvis and femur of 20 patients with Crowe type Ⅲ DDH who were treated in the First Affiliated Hospital of Harbin Medical University from September 2017 to October 2021 were reconstructed. The appropriate cup size was selected for implant simulation at the true acetabulum, the false acetabulum, and the site where the most abundant bone stock between the true and false acetabulum locates, then the acetabular cup host bone coverage ratio was calculated. The data were divided into true acetabulum group, intermediate group, and false acetabulum group.Results The mean size of the reconstructed acetabular cup of the intermediate group and false acetabulum group was larger than the true acetabulum group, and the difference between the true acetabulum group and the other two groups were significant, and there was no significant difference in acetabular cup size between the intermediate group and false acetabulum group. The mean host bone coverage ratio in each group was above 75%, and the value of the intermediate group was significantly different from that of the false acetabulum group.Conclusion In THA for DDH Crowe typeⅢ patients, acetabular cup placement at the false acetabulum or the site between true and false acetabulum can obtain larger acetabular cup size and satisfactory host bone coverage ratio.
查看全文  查看/发表评论  下载PDF阅读器
扫码关注
《生物骨科材料与临床研究》微信公众号